APPLICATIONS
- EMC Compliance testing Conducted emissions
- EMC Compliance testing Conducted immunity
- EMC Compliance testing Radiated emissions
- EMC Compliance testing Radiated immunity testing
KEY FEATURES
- EMC Chamber Dimensions (Internal shield) 5.5 m x 5.5 m x 3.5 m
- Typical 2.5m wide test bench
- Note Dimensions may vary, dependent on the dimensions of the equipment under test for e.g. a test bench or aircraft
- EMC Compliance for Emission/Immunity performance
- Absorbers compliant with MIL STD requirement -6dB 80-250MHz and -10dB > 250MHz
- Performance range 80 MHz - 40000 MHz
- Independently certified 100 dB @ 18 GHz shielding performance (EN50147-1)
- EMC absorbers ULTRA UHC series polypropylene based Broadband electromagnetic
- Optional Commercial testing with HyPyr-Loss™ Ferrite and Hybrid Lining available
- Optional High power absorbers available for radar and other applications
- Optimized computer modeling to enable cost effective EMC absorbers layouts
- This EMC Chamber is a Bespoke and modular design enabling unlimited performance options and facilitating upgrades or relocations
- This EMC Chamber is available as part of a complete turnkey package for EMC measurements